FV1200 Lasers and Fluorescence Filters
Lasers
This microscope is equipped with a pulsed 405 diode, 559 DPSS, 440 & 635 diodes, and an argon laser with 458, 488, 515 lines.
Detectors
2x Spectral detectors - The spectral detectors on this microscope has a range of 400nm to 800nm. The width can be set between 1nm and 100nm.
1x PMT
2x HSD - High sensitivity GaAsp Detectors.
Filter cubes in the microscope
These filters are only used when you view your specimen down the microscope eyepieces. The filter turret will automatically rotate to Position 1 (LSM) when you start scanning with the confocal.
Position Number | Filter Set | Excitation Filter | Dichroic Mirror | Emission Filter | Example Fluorophores |
---|---|---|---|---|---|
1 | LSM | N/A | N/A | N/A | Empty - for confocal imaging |
2 | U-FUW | 340 - 390 | 410 | 420IF | DAPI, Hoechst |
3 | U-FBNA | 470 - 495 | 505 | 510IF | FITC, Alexa 488 |
4 | U-FGWA | 530 - 550 | 570 | 575IF | TRITC, Texas Red |
5 | U-FCFP | 425 - 445CFP | 455CFP | 460 - 510CFP | CFP |
6 | U-FGFP | 460 - 480GFP | 490CFP | 495 - 540GFP | GFP |
7 | U-FF | N/A | N/A | N/A | Empty |
8 | IX3-FDICT | N/A | N/A | N/A | DIC Analyser |
Excitation Dichroics
Position Number | Excitation Dichroics | Example Fluorophores |
---|---|---|
1 | BS 20/80 | |
2 | DM 405/488 | DAPI, FITC |
3 | None | Empty |
4 | DM 405/488/559/635 | DAPI, FITC, TRITC, Cy5 |
5 | DM 458/515 | CFP, YFP |
6 | None | Empty |
Emission Filters in the light paths
Filters in CHS1, CHS2 & CHS3 light path
Detector | Dichroic Mirror | Function | Wavelengths passed | Example Fluorophores | Notes |
---|---|---|---|---|---|
CHS1 | Mirror | Reflects all light to CHS1 | See details of spectral detectors above | ||
Glass | Passes all light through to other detectors | ||||
SDM560 | Directs light below 560nm to CHS1, and the rest to the other detectors | Below 560nm | Acridine Orange | ||
SDM510 | Directs light below 510nm to CHS1, and the rest to the other detectors | Below 510nm | CFP | ||
SDM490 | Directs light below 490nm to CHS1, and the rest to the other detectors | Below 490nm | Dapi | ||
CHS2 | Mirror | Reflects all light to CHS2 | |||
Glass | Passes all light through to other detectors | ||||
SDM640 | Allows light below 640nm to CHS2, and the rest to the other detectors | Below 640nm | TRITC, Texas Red | ||
SDM560 | Allows light below 560nm to CHS2, and the rest to the other detectors | Below 560nm | GFP, FITC, AF488 | ||
CH3 | Mirror | Reflects all light to CH3 | This is a PMT with band pass filters before the detector | ||
Glass | Passes all light through to HSD detectors | ||||
SDM640 | Allows light below 640nm to CH3. Passes light above 640nm to HSDs | Below 640nm | There are three band pass filters available for CH3. A 655-755, 575-675 and a 575-620. |
Filters in HSD1&2 scanhead
Dichroic mirrors splitting light between HSD1 & 2
(These dichoics send the shorter wavelengths to HSD1 and longer wavelengths to HSD2
- DM505
- DM570
- DM485
- SDM510
- SDM570
- SDM640
Band pass filters to HSD1
- BA460-600
- BA495-540HQ
- BA420-460
- BA465-485
- BA480-495
- BA505-540
- BA490-540
- BA575-620
Band pass filters to HSD2
- BA520-560
- BA575-630
- BA495-540HQ
- BA605-680
- BA535-565
- BA575-675
- BA655-755